    Ceramic resonators have a typical accuracy of +/-0.5%. An error of +182Hz is a +0.57% error rate.

    Here is a datasheet cited by the Wikipedia article. It says 0.5% initial error, another 0.3% over its full temperature range, and another 0.3% over 10 years of aging.

    • AbidanYre@lemmy.world
      link
      fedilink
      English
      arrow-up
      27
      ·
      16 hours ago

      I guess “SNES operating within spec after 30 years” doesn’t grab attention the same way.